ASSOCIATION BETWEEN IOL DESIGN AND INCIDENCE OF PCO AND ND-YAG CAPSULOTOMY- A RETROSPECTIVE REAL WORLD EVIDENCE STUDY IN THE UK

Author(s)

Dhariwal M1, O'Boyle D2, Bouchet C1, Khan J3, Venerus A3, Muthutantri A3
1Alcon Laboratories, Inc, Fort Worth, TX, USA, 2Novartis Ireland Limited, Dublin, Ireland, 3IQVIA, London, UK

OBJECTIVES: Patients post-cataract surgery may experience abnormal proliferation of lens epithelial cells on the posterior capsule (posterior capsule opacification, PCO). Neodymium-doped yttrium aluminium garnet (Nd:YAG) laser capsulotomy is considered a safe surgical treatment for PCO, but could occasionally lead to further complications. Existing studies have reported numerous factors influencing PCO incidence including IOL material and design. In this study, real-world incidence of both PCO and Nd:YAG in the 5 years post-cataract surgery were assessed in a large UK population, including their association with IOL material.

METHODS: Patients (≥65 years) undergoing cataract surgery with ‘in-the-bag’ placement of acrylic monofocal single-piece IOLs between 2010-2013 were included. Data were collected from Electronic Medical records (EMR) from 7 UK NHS Ophthalmic clinics; only IOL models used in at least 500 procedures were included. The analysis focused on the association between the IOL model and the risk of PCO and Nd:YAG. Incidence proportion of PCO and Nd:YAG at 5 years from cataract surgery was calculated for each IOL model. Pairwise comparisons were conducted between AcrySof IOLs and other IOLs using Bonferroni adjustment for multiplicity. Multivariate analyses were also conducted adjusting for known confounders.

RESULTS: Incidence proportion of Nd:YAG at 5 years post-cataract surgery was 5.8% for AcrySof (CI 5.2%-6.4%, n=5,342); this was significantly lower than Tecnis (8.5%, CI 7.8%-9.2%, n=5,609), B&L (15.2%, CI 14.3%-16.0%, n=6,847) and Lenstec (19.3%, CI 17.9%-20.8%, n=2,964) (all P values <0.001). AcrySof IOLs also had significantly lower incidence proportion of PCO compared with the other IOLs.

CONCLUSIONS: This real world evidence study demonstrated that hydrophobic single-piece AcrySof IOLs are associated with a significantly lower incidence of Nd:YAG capsulotomy and PCO post cataract surgery, at a long-term follow-up of five years.

Conference/Value in Health Info

2018-11, ISPOR Europe 2018, Barcelona, Spain

Value in Health, Vol. 21, S3 (October 2018)

Code

PMD24

Topic

Epidemiology & Public Health

Disease

Sensory System Disorders

Explore Related HEOR by Topic


Your browser is out-of-date

ISPOR recommends that you update your browser for more security, speed and the best experience on ispor.org. Update my browser now

×