COMPARATIVE EFFECTIVENESS ANALYSIS IDENTIFIES A SUPERIOR POINT OF CARE DEVICE FOR ASSESSING THE INTERNATIONAL NORMALIZED RATIO

Author(s)

Shermock KM1, Streiff MB2, Kraus P1, Pinto BL1, Lavallee DM31The Johns Hopkins Medical Institutions, Baltimore, MD, USA, 2The Johns Hopkins University School of Medicine, Baltimore, MD, USA, 3Lovelace Respiratory Research Institute, Sykesville, MD, USA

OBJECTIVES: Comparative effectiveness research identifies superior clinical devices or treatments through head-to-head comparisons.  This study describes the use of an innovative framework to assess the quality and safety of two INR Point of Care devices. METHODS: Patients enrolled in the hematology Anticoagulation Management Service provided three INR measures: one venous sample analyzed by our lab (considered the standard measure), one fingerstick analyzed by the Hemochron Signature Elite POC device and another fingerstick by the Coaguchek XS Plus.  Agreement between INR values from each device and the lab was assessed.  Agreement was achieved when the INR measures were predicted by a novel, validated method to lead to the same clinical decision.  Differences in agreement between the POC devices and the lab were assessed using McNemar’s test of paired proportions.  RESULTS: Ninety-nine subjects were enrolled into the study.  There was significantly less difference between INR values from the Coaguchek XS device and the lab compared to the Hemochron device (average absolute difference = 0.24 vs 0.41 p<0.05).  The Hemochron device tended to report both high and low INR values were within the target range when the laboratory said otherwise.  Consequently, the Hemochron device was significantly more likely to lead to a different clinical decision than the core laboratory compared to the Coaguchek XS (30% vs. 18%, respectively; RR: 1.7, 95% CI: 1.1-2.4, P=0.007). CONCLUSIONS: Comparative effectiveness analysis can provide essential information to make informed decisions when selecting medical devices to be utilized in clinical practice.  The analytic framework in this comparative effectiveness analysis demonstrated the Coaguchek XS device to have a significantly higher level of agreement with the core lab compared to the Hemochron device.   This analysis led our institution to select the Coaguchek XS for use in our anticoagulation clinics on the basis of a superior quality and safety profile.

Conference/Value in Health Info

2010-05, ISPOR 2010, Atlanta, GA, USA

Value in Health, Vol. 13, No. 3 (May 2010)

Code

PCV14

Topic

Clinical Outcomes

Topic Subcategory

Comparative Effectiveness or Efficacy

Disease

Cardiovascular Disorders, Respiratory-Related Disorders

Explore Related HEOR by Topic