VALIDATION AND COMPARISON OF THE SF-6D AND EQ-5D IN CHINESE PATIENTS WITH STABLE ANGINA PECTORIS
Author(s)
Wu J1, Han Y1, Gao Y2, Zhou J3, Chen Z4, Sun H11Tianjin University, Tianjin, China, 2Southwestern University of Finance and Economics, Chengdu, Sichuan, China, 3Tianjin Chest Hospital, Tianjin, China, 4Affiliated Hospital of Logistics University of Chinese People's Armed Police Force, Tianjin, China
OBJECTIVES: To validate and compare the psychometric properties of two generic preference-based HRQoL instruments, EuroQol (EQ-5D) and Short-Form 6D (SF-6D) among stable angina pectoris (SAP) patients in China. METHODS: Validity of the EQ-5D and SF-6D was examined with eight a priori hypotheses from a consecutive sample (n=411, mean age 68.1+/-11.3) of SAP patients in conjunction with Seattle Angina Questionnaire (SAQ). Responsiveness was tested using the effect size (ES), relative efficiency (RE) and receiver operating characteristic (ROC) curves. Agreement between EQ-5D and SF-6D was tested using intra-class correlation coefficient (ICC) and Bland-Altman plot. Factors affecting utility difference were explored with multiple liner regression analysis. RESULTS: The mean utility scores (SD) were 0.75(0.19) for EQ-5D and 0.68(0.12) for SF-6D. Validity was demonstrated by the moderate to strong correlation coefficients (range: 0.404-0.594, P<0.001) for four of the eight hypotheses in both EQ-5D and SF-6D. There were no serious ceiling effects for EQ-5D and SF-6D but floor effects for EQ-5D were large. SF-6D showed a better discriminative capacity (ES=0.573-1.179) between groups with different SAP-specific health status than EQ-5D (ES=0.385-0.851). RE showed that SF-6D (32.7-218.7%) was more efficient than EQ-5D. The areas under ROC of them all exceeded 0.5 (0.661-0.814, P<0.001). Poor agreement between them was observed with ICC (0.477, P<0.001) and Bland-Altman plot analysis. Multiple liner regression showed that clinical variables significantly (P<0.05) influenced differences in utility scores between EQ-5D and SF-6D. CONCLUSIONS: This study provides evidence that EQ-5D and SF-6D are valid and sensitive preference-based HRQoL instruments in Chinese SAP patients. SF-6D may be a more effective tool with lower flooring effect and greater sensitivity. Further study is needed to compare other properties, such as reliability and longitudinal response.
Conference/Value in Health Info
2012-09, ISPOR Asia Pacific 2012, Taipei, Taiwan
Value in Health, Vol. 15, No. 7 (November 2012)
Code
PCV36
Topic
Patient-Centered Research
Topic Subcategory
Patient-reported Outcomes & Quality of Life Outcomes
Disease
Cardiovascular Disorders