PSYCHOMETRIC DEVELOPMENT OF A NEW PRO INSTRUMENT- THE FACE-Q SCALES FOR FACELIFT PATIENTS
Author(s)
Cano S*1;Pusic A2;Scott A2, Klassen A3 1ScaleReport, Stotfold, United Kingdom, 2Memorial Sloan-Kettering Cancer Center, New York, NY, USA, 3McMaster University, Hamilton, ON, Canada
OBJECTIVES: Improved satisfaction with facial appearance is the primary desired outcome for patients undergoing facelift procedures. The FACE-Q is a new patient-reported outcome (PRO) instrument composed of scales to evaluate a range of outcomes (appearance concerns, quality of life, adverse effects) for patients undergoing any type of facial cosmetic surgery, minimally invasive cosmetic procedure or facial injectable. The objective of this study was to describe the development and psychometric properties of a set of FACE-Q scales relevant to measuring outcomes in facelift patients. METHODS: The FACE-Q was developed according to international guidelines for PRO instrument development. Scales relevant to facelift patients include five appearance scales (each with five items) covering the following facial areas: cheeks, lower face and jawline, nasolabial folds, area under the chin, and neck. In addition, an adverse effects checklist was developed to measure postoperative symptoms and complications. Data were collected in a larger study that included 225 facelift patients (all had surgery within the past 5 years) between June 2010 and June 2012 (response rate 78%). Rasch measurement theory (RMT) analyses was used to examine clinical meaning, thresholds for item responses, item fit, item locations, differential item functioning (DIF), standardized residuals, and person separation index (PSI). RESULTS: Participants were aged 36 to 77 years and 205 were female. The five appearance scales were found to be clinically meaningful, reliable, valid and responsive to clinical change. Specifically, RMT findings were as follows: no disordered thresholds; overall and individual item fit statistics (29/30 items -2.5/+2.5); no DIF by gender, age or ethnicity; PSI > 0.88 (0.88-0.90). Cronbach’s alpha were all >0.94 (0.94-0.97). CONCLUSIONS: The FACE-Q scales for facelift patients are scientifically sound and clinically meaningful scales that may be used to measure the impact of facelift surgery on patient satisfaction.
Conference/Value in Health Info
2013-05, ISPOR 2013, New Orleans, LA, USA
Value in Health, Vol. 16, No. 3 (May 2013)
Code
PIH36
Topic
Patient-Centered Research
Topic Subcategory
Stated Preference & Patient Satisfaction
Disease
Multiple Diseases, Reproductive and Sexual Health, Respiratory-Related Disorders