QUALITATIVE EQUIVALENCE BETWEEN A PAPER AND ELECTRONIC TABLET VERSION OF THE WOMAC®NRS3.1 AND PATIENT GLOBAL ASSESSMENT
Author(s)
Eremenco S1, Fleming S2, Riordan D3, Stringer S1, Gleeson S1, Sanga P4, Kelly K5
1Evidera, Inc., Bethesda, MD, USA, 2Janssen Global Services, Titusville, NJ, USA, 3Janssen Research and Development, Raritan, NJ, USA, 4Janssen Research and Development, Titusville, NJ, USA, 5Janssen Research and Development L.L.C., Titusville, NJ, USA
OBJECTIVES Prior equivalence work with the WOMAC® scale was published for the VAS scale and older touchscreen computer technology. Additional equivalence evaluation of the WOMAC®NRS3.1 and the Patient Global Assessment (PGA) in a newer tablet with stylus was needed to document suitability of this mode of data collection for these instruments in upcoming clinical trials. METHODS A cross-sectional qualitative study was conducted involving cognitive and usability interviews with patients diagnosed with osteoarthritis of the hip or knee who were taking pain medication for their condition. Interviews were conducted in two waves of 10 participants each, with revisions to the PGA made in between the rounds, which allowed for changes to the electronic version to be evaluated. RESULTS Mean age of the sample (N=20) was 66 years, (range 43-78), 90% over 60 years old; 60% were female; 95% were white; 75% were retired; 70% had completed secondary school or some college, while 30% had completed college or a post-graduate degree. In wave 1, minor issues were found with completing the WOMAC®, mainly with using the stylus to select responses and glare on the screen. There were no issues identified in interpreting the response scale. For the PGA, 50% (5/10) used the wrong recall period (48 hours or longer). The PGA recall period was revised from “at this time” to “over the past 24 hours” and bolded for emphasis. In wave 2, similar issues with glare and stylus response were found, while 80% used the correct recall period on the PGA, with 20% using 48 hours. CONCLUSIONS The study showed excellent qualitative equivalence between the paper and electronic WOMAC® with only minor usability issues. The two wave study design provided the opportunity to detect and make changes to the PGA recall period and formatting that showed improvement in the second wave.
Conference/Value in Health Info
2014-11, ISPOR Europe 2014, Amsterdam, The Netherlands
Value in Health, Vol. 17, No. 7 (November 2014)
Code
PMS75
Topic
Patient-Centered Research
Topic Subcategory
Patient-reported Outcomes & Quality of Life Outcomes
Disease
Musculoskeletal Disorders