COMPARISON OF RESOURCE UTILIZATION AND POTENTIAL COST SAVINGS FOLLOWING SCREENING WITH DIGITAL BREAST TOMOSYNTHESIS COMPARED WITH DIGITAL MAMMOGRAPHY

Author(s)

Conant EF1, Menon V2, Behling M2, Lafontant A2, Donadio G2, Su Z2, Troeger KA3, Pohlman SK3, Talley M4, Alsheik NH5
1Hospital of the University of Pennsylvania, Philadelphia, PA, USA, 2OM1, Boston, MA, USA, 3Hologic, Inc., Marlborough, MA, USA, 4Sanford Health, Sioux Falls, SD, USA, 5Advocate Caldwell Breast Center, Park Ridge, IL, USA

OBJECTIVES

To examine follow-on diagnostic imaging testing pathways following breast cancer screening with digital mammography (DM) alone versus in combination with digital breast tomosynthesis (DBT) in a large representative cohort.

METHODS

A big data platform was used to integrate electronic medical record, radiology information system, and tumor registry data. The analysis included 626,346 screening mammograms, from 364,833 unique women, performed 2015 to 2018, from 64 imaging facilities across three large geographically varied healthcare organizations. Positive screens were defined as the proportion of screening mammography examinations with BI-RADS categories 0, 3, 4, and 5 assessments. Diagnostic evaluation pathways were defined as the series of imaging procedures during the 90 days following a positive screen. Pathways were defined empirically based on the observed sequence of imaging examinations and biopsy.

RESULTS

There were 393,410 (62.8%) DBT screening exams versus 232,936 (37.2%) DM. Average age was 58.4±10.1 years; women screened with DBT had dense breasts (48.3% vs 39.3%) and higher lifetime risk for breast cancer (10.1% vs 7.3%). 36,046 (9.2%) of women had a positive screening exam after DBT versus 23,889 (10.3%) after DM. Women receiving DBT were more likely to proceed directly to ultrasound (15.9% DBT vs 4.2% DM, p<.0001). The most common diagnostic pathway after a positive exam for both screening modalities was mammography and ultrasound (39.4% DBT and 43.6% DM). The next most common pathway was diagnostic mammogram alone (21.8% DBT and 30.7% DM).

CONCLUSIONS

DBT is associated with more efficient screening pathways and lower downstream imaging resource utilization. This may be attributed to improved lesion conspicuity and localization on DBT images potentially precluding the need for additional diagnostic mammographic imaging following screening. Further analysis will use cost estimates for associated procedures in order to evaluate the value and potential cost savings associated with DBT screening compared to DM.

Conference/Value in Health Info

2019-05, ISPOR 2019, New Orleans, LA, USA

Value in Health, Volume 22, Issue S1 (2019 May)

Code

PCN239

Topic

Medical Technologies

Topic Subcategory

Diagnostics & Imaging

Disease

Oncology

Explore Related HEOR by Topic


Your browser is out-of-date

ISPOR recommends that you update your browser for more security, speed and the best experience on ispor.org. Update my browser now

×