Quality of Life Analysis for Patients with Essential Tremor Receiving Magnetic-Resonance Image-Guided Focused Ultrasound Treatment: Three Years of Follow-Up
Author(s)
Richard L1, Mañez-Miró J2, Ghosh W3, Chatzidaki I4, Ostrander B1, Martínez-Fernández R2
1INSIGHTEC Ltd, Tirat Carmel, Israel, 2CINAC-Hospital Universitario HM Puerta del Sur, CEU-Universidad San Pablo, Madrid, Spain, 3Costello Medical Singapore, Singapore, Singapore, 4Costello Medical, Cambridge, UK
OBJECTIVES There are limited EQ-5D data associated with magnetic-resonance image-guided focused ultrasound (MRgFUS) in essential tremor (ET), which has limited cost-utility analyses. This research aimed to obtain and perform descriptive analyses on utility values from EQ-5D-3L data of ET patients receiving MRgFUS. METHODS The UK value set by Dolan et al. was used to generate utility values from EQ-5D-3L data collected for 191 ET patients in the ND001 registry (data cut-off March 2020), a global observational study on the effectiveness of MRgFUS for neurological disorders. Mean utility values were calculated for the 8 timepoints of follow-up (baseline to 3 years). An analysis of variance (ANOVA) model compared the change in mean utility value from baseline, at each timepoint. Random effects for patient identity were considered, to account for correlated observations from the same patient at different timepoints. A linear regression model investigated the relationship between mean utility values and time, using random effects for patient identity. RESULTS Mean utility values in all timepoints of follow-up were significantly improved from baseline. The mean utility value at baseline (0.647) increased rapidly until month 6 and remained constant thereafter, at approximately 0.850. The highest change in mean utility value from baseline was observed at 6 months (0.196, p<0.001). Estimates from year 3 had greater uncertainty, due to lower sample size. The linear model showed a small but statistically significant increase of 0.004 in mean utility values per month (p<0.001). However, the data did not follow a linear trend, therefore the ANOVA model was deemed more reliable. CONCLUSIONS The analysis suggests that MRgFUS improves the quality of life over time, but this increase is likely not linear and stabilises after approximately 6 months of follow-up. Further investigation is needed to assess the relationship of quality of life over time with other clinical outcomes.
Conference/Value in Health Info
2020-11, ISPOR Europe 2020, Milan, Italy
Value in Health, Volume 23, Issue S2 (December 2020)
Code
PND102
Topic
Medical Technologies, Patient-Centered Research
Topic Subcategory
Medical Devices, Patient-reported Outcomes & Quality of Life Outcomes
Disease
Medical Devices, Neurological Disorders