Mortality after Use of paclitaxel-Based Devices in Peripheral Arteries : A Real-World Analysis
Author(s)
Choi H, Lee H, Lee SS
Medtronic Korea, Seoul, Korea, Republic of (South)
OBJECTIVES : Drug technology for the treatment of peripheral arterial disease (PAD) have been an emerging concept for many years thanks to improve the freedom from target lesion revascularization (TLR). However, recent meta-analysis published in 2018 caused a cataclysm in the vascular field reporting higher mortality in the patients treated with paclitaxel-based devices. Therefore, we analyzed the mortality among 4 treatment groups using administrative claims data provided by National Health Insurance Service (NHIS) in Korea. METHODS : We identified the patients with PAD procedures from August 2015 to December 2017 and classified the patients into 4 groups; plain old balloon angioplasty (POBA), drug coated balloon(DCB), bare metal stent(BMS) and drug eluting stent(DES). All-cause mortality incidence was analyzed using Kaplan-Meier method and multivariable cox proportional hazard model was used to find risk factors associated with the mortality. RESULTS : Total 1,742 patients with PAD procedures were identified(POBA 501, DCB 816, BMS 310 and DES 97). The 2-year mortality rate was highest in POBA group with statistical significance; POBA 27.7%, DCB 17.9%, BMS 22.3%, DES16.5% (P=0.0001). At the multivariate analysis, the risk factors of mortality were age (adjusted hazard ratio aHR, 1.058; 95% CI, 1.046-1.071), sex (aHR 1.355; 95% CI, 1.079-1.702), chronic renal failure (aHR 2.812; 95% CI, 2.232-3.543), hyperlipidemia (aHR 0.660; 95% CI, 0.522-0.834) and ischemic stroke (aHR 1.709 ; 95% CI, 1.377-2.122). As a result of comparison between paclitaxel based devices (DCB and DES) and non-paclitaxel based devices (POBA and BMS), cox regression analysis showed paclitaxel devices were associated with decreased mortality (aHR 0.746; 95% CI, 0.606-0.920). CONCLUSIONS : Our real-world analysis found that the use of paclitaxel based devices to be safe for endovascular therapy of peripheral artery. Particularly with regard to 2-year mortality, neither DCB nor DES was associated with increased risk compared to non-paclitaxel devices.
Conference/Value in Health Info
2020-09, ISPOR Asia Pacific 2020, Seoul, South Korea
Value in Health Regional, Volume 22S (September 2020)
Code
PMD8
Topic
Clinical Outcomes, Medical Technologies, Organizational Practices
Topic Subcategory
Clinical Outcomes Assessment, Comparative Effectiveness or Efficacy, Industry, Medical Devices
Disease
Cardiovascular Disorders