A PROSPECTIVE PRAGMATIC CLINICAL TRIAL TO COMPARE THE REAL-WORLD USE OF A WEARABLE INSULIN DELIVERY DEVICE TO STANDARD TREATMENT OPTIMIZATION IN TYPE 2 DIABETES PATIENTS WITH POOR GLYCEMIC CONTROL USING MULTIPLE DAILY INSULIN INJECTIONS

Author(s)

Abbott S1, Strange P2, Shi L2, Nguyen M3, Larholt KM4, Wasser T4, Cziraky MJ4
1Valeritas, Zionsville, IN, USA, 2Integrated Medical Development, Princeton Junction, NJ, USA, 3Valeritas, Bridgewater, NJ, USA, 4HealthCore Inc., Wilmington, DE, USA

OBJECTIVES:  This prospective pragmatic clinical trial (PCT) evaluated a wearable insulin delivery device (V-Go) compared to a standard treatment optimization control (STO) in a community-based practice setting. The primary outcome was the change in A1C from baseline to end of study (EOS). Treatment cost and effectiveness analyses in patients receiving multiple daily insulin injections (MDI) were conducted. METHODS:  This cluster randomized trial, where study sites rather than individual patients, were randomized to initiate V-Go and stop other insulin therapy or to continue diabetes treatments. Patients taking insulin were enrolled in both groups and treated according to routine practice for up to 4 months. All treatments and medications were obtained by usual care utilizing patient health insurance. RESULTS:  The analysis population included 52 sites in the United States with 246 STO and 169 V-Go patients. Baseline A1C ranged from 7.9 to 14.2% and was higher for V-Go vs. STO (9.88% vs. 9.34%; p<0.001) indicating a selection bias to initiate V-Go in more advanced diabetes patients. Significant A1C decreases from baseline to EOS with V-Go (-0.95%, p<0.001) and STO (-0.46%, p<0.001) and for V-Go vs. STO (p<0.002) were observed. To control for the baseline and treatment imbalance of the overall cohort, cost and efficacy analyses in patients utilizing comparable baseline diabetes treatment, basal bolus insulin injections, were performed. V-Go (n=95) had higher mean baseline A1C than STO (n=113), 9.895% vs 9.374%, and a larger change from baseline of -1.015% vs -0.377%; p<0.01. The mean per patient per day (PPPD) cost of diabetes treatment, using Wholesale Acquisition Cost (WAC) and including all concomitant diabetes medications and devices, was $32.60 for STO compared to $30.59 for V-Go patients. CONCLUSIONS:  This PCT demonstrated improved diabetes treatment outcomes and total diabetes treatment cost in patients with poor diabetes control initiating a wearable insulin delivery device in a real-world setting.

Conference/Value in Health Info

2017-05, ISPOR 2017, Boston, MA, USA

Value in Health, Vol. 20, No. 5 (May 2017)

Code

PMD39

Topic

Economic Evaluation

Topic Subcategory

Cost/Cost of Illness/Resource Use Studies, Cost-comparison, Effectiveness, Utility, Benefit Analysis

Disease

Diabetes/Endocrine/Metabolic Disorders

Explore Related HEOR by Topic


Your browser is out-of-date

ISPOR recommends that you update your browser for more security, speed and the best experience on ispor.org. Update my browser now

×